APPLICATIONS - page 1 of 3
View our latest ad which illustrates how Teledyne
addresses the needs of the petrochem industry.
INDUSTRY SERVICE PARAMETER RANGE BACKGROUND TELEDYNE MODEL
Ethyl Benzene / Styrene Monomer
Raytheon Badger, ABB Lummas
Styrene vent gas PPM oxygen 0-2000 ppm O2 H2 / N2 / CO2 / mix 3000TB / 3020T / 318R
Transalkylation regen gas Percent oxygen 0-15% O2 O2 / N2 / CO / CO2 3000PB / 328R
Transalkylation regen gas Percent CO / percent CO2 0-20% CO / 0 - 20% CO2 O2 / N2 / CO / CO2 IR-7000 (Z-purged)
Stacked gas (2-4 sets) Percent O2 0-5% O2 Flue gas 9060 ZrO2
Stripped condensate Hydrocarbons 0-10 ppm HC Condensate (H20) 6600 (UV) / 660C
Cooled condensate Hydrocarbons 0-100 ppm HC Condensate (H20) 6600 (UV) / 660C
EB recycle stream PPM H2O (L) 0-300 ppm H20 Benzene 510 (NIR)
Polystyrene
DOW
Headspace of styrene tanks
(special Teledyne probe applied)
Percent O2 0-5% O2 N2 / Styrene vapors Series 322 / 327
(6 to 12 pts)
INDUSTRY SERVICE PARAMETER RANGE BACKGROUND TELEDYNE MODEL
Ethylene oxide / Ethylene glycol
Scientific Design
Ethylene feed / Reactor inlet and reactor outlet Percent C2H4 0-20%, 0-40% C2H4 CO2 / AR / CH4 IR7000 / 730
Ethylene feed / Reactor inlet and reactor outlet Percent O2 0-10%, 0-25% O2 CO2 / AR / CH4 3020P / 328R
(Paramag Spec)
EO purification unit Percent LEL 0-100% combustibles Ambient air 1220
Ethylene glycol product Percent H2O (L) 0-5% H2O Ethylene glycol 510
Acetone / Phenol / Cumene
M.W. Kellogg
Oxidizer vent gas (No. 1 & 2) Percent O2 0-10%, 0-25% O2 N2, Cumene, H2O 3020P / 328 (Paramag spec)
(total of 4 sets required)
Recycle compressor drum gas Percent H2 50-100% H2 N2, CH4 2020 / 238 (TCD)
Acetone product to storage Percent H2O (L) 0-0.5%, 0-5% H2O (L) Acetone 510 (NIR)
Heavy ends fired boiler Percent O2 0-5% O2 Flue gas 9060 ZrO2
EDC / VCM
B.F. Goodrich
Absorber vent gas Percent O2 0-5% O2 CO2 / H20 / CL2 / HCL Paramagnetic required
Stripper vent gas Percent O2 0-5% O2 CO2 / H20 / CL2 / HCL Paramagnetic required
VCM vent gas PPM O2 0-10 / 0-100 PPM O2 VCM (G) 3020T / 318R
H2O in EDC PPM H20 (L) 0-50 / 0-200 PPM H2O EDC (pure) 510 (NIR)
Typically 4 to 5 sets
CL2 in EDC PPM CL2 (L) 0-1000 PPM CL2 EDC (pure) 6020 UV
H20 in TCE / PCE
Oxyhydrochlorination route vent gas
Percent CO 0-20% N2 / CO2 / C2H4 IR7000 / 730
Percent CO2 0-20% N2 / CO2 / C2H4 IR7000 / 730
Percent C2H4 0-40% N2 / CO2 / C2H4 IR7000 / 730
INDUSTRY SERVICE PARAMETER RANGE BACKGROUND TELEDYNE MODEL
Acrylonitrite
B.P. Chemical
Product storage inhibitor PPM / Percent H2O (L) 0-2000 PPM, 0 - 1% Acrylonitrile (pure) 510 (NIR)
Product storage inhibitor MethylHydroquinone 0-100 PPM MEHQ (L) Acrylonitrile (pure) 6020 (UV)
Product storage / N2 blanket Percent O2 0-10% O2 AcryloVapors + N2 3020T / 328R
MethylMethacrylate
ICI
ACH vent blower - safety Percent O2 0-5% O2 (Alarm @ 2%) N2 + HCN + Acetone 3020T / 328R
Acetic Acid
B.P. Chemical
Reactor system - liquid effluent Percent H2O (L) 0-20% Acetic acid - HOAC 510 (NIR)
Drying column - side Percent H2O (L) 0-20% Acetic acid - HOAC 510 (NIR)
Drying column - bottoms PPM H2O 0-1500 PPM Acetic acid - HOAC 510 (NIR)
Flare gas header PPM methyl iodide 0-1000 PPM CO / CO2 / N2 / H2 6020 (UV)
Combined off gas PPM methyl iodide 0-1000 PPM CO / CO2 / N2 / H2 6020 (UV)
Combined off gas Percent H2 0-30% CO / CO2 / N2 / H2 2020 / 238 (TCD)
Promoter off gas Percent H2 0-30% CO / CO2 / N2 / H2 2020 / 238 (TCD)
Steam condensate / leaving plant PPM Hydrocarbons 0-10 PPM Condensate (H2O) 6600 (UV) / 402R (FID) + 1100A
PPM O2 0-150 PPM CO (90%) 3020T / 318R
INDUSTRY SERVICE PARAMETER RANGE BACKGROUND TELEDYNE MODEL
Titanium Dioxide
DuPont; Kronos; Kemira; Kerr-McGee; SCM Chemicals
Chlorinator exit gas PPM CL2 0-1000 PPM TiCL / N2 / CO2 6000 (UV)
Stack vent gas PPM CL2 0-500 PPM CO2 / N2 / CO 6000 (UV)
Stack vent gas PPM SO2 0-500 PPM CO2 / N2 / CO 6000 (UV)
Process PPM Vanadium (L) 0-10 PPM CCL4 6000 (UV)
Ammonia / Urea Fertilizer Plants
Snamprogetti; M.W. Kellogg
Primary and secondary rfmr outlet Percent CH4 - 3 sets 0-0.5% up to 0-20% H2 / CO2 / CO / N2 IR-7000 (NDIR)
HTS / LTS shift converter outlet Percent CO - 2 sets 0-0.5% up to 0-5% H2 / CO2 / CO / N2 IR-7000 (NDIR)
Absorber outlet Percent CO2 - 2 sets 0-0.3% and 0-1.5% H2 / CO2 / CO / N2 IR-7000 (NDIR)
Methanator and NH3 converter outlet Percent H2 - 2 sets 50-100% N2 / CH4 2020 / 238 (TCD)
Percent O2 - 2 sets 0-0.5% O2 N2 / H2 / CO2 3020T / Paramagnetic spec
CO2 Feed to urea plant Percent O2 0-1% CO2, H2, N2, Ar 3000 Series
Stack gas Percent O2 - 2 sets 0-5% and 0-10% O2 N2 / CO2 / O2 / H2Ov 9060 ZrO2
Treated waste water Oil / Hydrocarbons 0-150 PPM Water 6600 (UV)
Vinyl Chloro Monomer (VCM)
Inlet of recovered VCM compressor Percent O2 0-1 and 0-5% VCM (96%), H2Ov 3020T / 328R
For more Petrochemical solutions utilizing Teledyne's broad product line, click for page two and page three.
 

Applications by industry - Petrochemical | Oil and Gas | Air Separation | Power Generation
Cement | Refining | Food and Beverage | Pharmaceutical
Steel | Pulp and Paper | Semiconductor | Various

Home | Site Map