APPLICATIONS
|
INDUSTRY
(FACILITY)
|
SERVICE
|
PARAMETER
|
RANGE
|
BACKGROUND
|
TELEDYNE MODEL
|
Flue Gas Desulferization (FGD)
|
Inlet to fluidized bed / absorber
|
Percent SO2
|
0-1%
|
Flue gas
|
Series 6000 UV
|
Outlet from fluidized bed / absorber
|
PPM SO2
|
0-250, 0-500 ppm
|
ON-LINE / CONTINUOUS
|
Excess O2
|
Stack gas analysis
|
Percent O2
|
0-5%
|
Flue gas
|
9060 (ZrO2)
|
Combustion efficiency
|
PPM CO
|
0-1000 ppm
|
IR-7000
|
Percent combustibles
|
0-5% CH4 eq
|
9700 for heavy, solid fuels
|
|
Pollution abatement
|
Continuous emission monitor
|
PPM SO2
|
0-250 to 0-5000 ppm
|
Flue gas
|
6000 (UV) / IR-7000 (NDIR)
|
CEM / Stack gas
|
PPM NOx
|
0-10 to 0-5000 ppm
|
911 Chemiluminescence
|
|
H2 cooled turbine generator
|
H2 purity
|
Percent H2
|
80-100%
|
Air
|
238TG
|
CO2 purge of H2 from turbine
|
Percent CO2
|
0-100%
|
H2
|
Air purge of CO2 from turbine
|
Percent Air
|
0-100%
|
CO2
|
|
Boiler tube control
|
Oil in boiler return steam condensate
|
PPM oil
|
0-10 ppm
|
Condensate
|
6600 (UV)
|
|
Cooling water
|
Hydrocarbons in cooling H2O
|
PPM hydrocarbons
|
0-10 ppm
|
Water
|
402R + 1100A stripper
|
|
APPLICATIONS
|
INDUSTRY
(FACILITY)
|
SERVICE
|
PARAMETER
|
RANGE
|
BACKGROUND
|
TELEDYNE MODEL
|
PORTABLE ANALYZERS
|
Excess O2 / Boiler
|
Stack gas analysis
|
Percent O2
|
0-5%
|
Flue gas
|
320P, 320PD
|
Percent O2; PPM CO Comb
|
See data sheet
|
Max 5
|
|
Pollution abatement
|
Stack gas analysis
|
Percent O2; PPM CO, SO2, NO, NO2; Percent CO2
|
See data sheet
|
Flue gas
|
9950
|
|
H2 Turbine generator
|
H2 purity / turbine maintenance
|
Percent H2, CO2, Air
|
See data sheet
|
Air, H2, CO2
|
275R
|
SF6 Filling
|
Electrical apparatus / switchbox
|
PPM O2
|
0-10 ppm
|
SFG
|
311
|
|
Nuclear power plant (PWR / BWR)
|
H2 containment building
|
Percent H2
|
0-30%
|
Air
|
225CM nuclear rated
|
Monitor
|
Percent O2
|
0-25%
|
|
Bechtel Spec
|
Battery room analysis
|
Percent H2
|
0-100% LEL
|
Air
|
102 / 1223 commercial grade
|
|
BNFL (UK)
|
Nuclear fuels conversion of uranium ores to UF6
Effluent control of fluorine
|
Percent F2
|
0-50%
|
UF6, HF, O2, CF4
|
Series 6000 UV (commercial)
|
|
KEPCO - Korea
|
Gaseous waste treatement
|
Percent O2
|
0-5, 0-10%
|
N2
|
Series 3000 (commercial)
|
|
KEPCO - Korea
|
Deuterium (D2) in air
|
Percent D2
|
0-5%
|
Air
|
Series 235 / Series 2000 (commercial)
|
|
APPLICATIONS
|
INDUSTRY
(FACILITY)
|
SERVICE
|
PARAMETER
|
RANGE
|
BACKGROUND
|
TELEDYNE MODEL
|
Vacuum Drag System
|
Recombiner (after condensor)
|
Percent H2
|
0-5% H2
|
O2 / N2
|
Series 235 / Series 2000 (commercial)
|
Feed to off gas compressors
aka Catalytic recombiner of radwaste gas mixture
|
Percent O2
|
0-5% O2
|
N2 / H2
|
326R / Series 3000 (commercial)
|
|
Desalination plant
|
Seawater electrochlorination unit efficiency performance
|
PPM NaOCL (hypochlorite ion)
|
0-1500 ppm
|
Seawater
|
Series 6000 (UV)
|